Notifications
Design created with a previous version of design engine |
|
PIXls file being opened is newer than the current version of PIXls |
|
Previous version of Design File |
|
Old version of Design File |
|
Both input and output parameters must be selected |
|
Input and output parameters must be different values |
|
Goal Seek failed to find a solution |
|
Calculation error: Change input parameters |
|
Identified value is less than the minimum limit |
|
Identified value is above the maximum limit |
|
Optimization failed: Change device and/or transformer selection |
|
Optimization failed: Core effective winding area is too small for the calculated number of turns |
|
Optimization failed: KP is below the minimum limit |
|
Optimization failed: Duty cycle (DMAX) above maximum limit |
|
Optimization failed: capacitance required for this power level (PO) cannot be found |
|
Optimization failed: No PI Component found for the specified output power (PO) |
|
Optimization failed: Do you want to review the "Best Fit" solution? |
|
Minimum Bias voltage required |
|
The UV turn-ON threshold value is too high |
|
The OV shutdown turn-OFF threshold value is too low |
|
No outputs specified |
|
Input value is too high |
|
Input value is too low |
|
Foil winding requires use of margin tape |
|
Output capacitor rated ripple current exceeded |
|
Transformer windings may not fit in the winding window |
|
Selected diode has no margin to its rated voltage. |
|
Selected diode has insufficient margin to its rated current |
|
Estimated clamp voltage is too high |
|
Estimated clamp voltage is too high (DPA) |
|
Total margin width exceeds the width of the bobbin |
|
TVS Clamps are not recommended for power levels exceeding 20 W |
|
Target clamping voltage is too low |
|
Some of the specified tolerances could not be met |
|
Some of the specified tolerances could not be met |
|
Optimization failed to find a solution |
|
Selected diode has less than 10% margin to its rated voltage |
|
SI Units were changed, Transformer will be redesigned |
|
Rated fuse voltage too low |
|
Rated input fuse current is too low |
|
Rated input fuse voltage is too low |
|
Fusible resistor in use |
|
Thermistor resistance too low |
|
Thermistor current rating is too low |
|
Input rectifier rated voltage is too low |
|
Input rectifier rated current is too low |
|
Calculated snubber cut-off frequency is too high |
|
Voltage rating of snubber capacitor is too low |
|
Snubber resistor power rating is too low |
|
The heatsink selected can be inadequate |
|
The X-capacitor discharge resistors are inadequate |
|
Post filter resonant frequency is too high |
|
Power rating of bias snubber resistor too small |
|
Rated voltage of input capacitor is too low |
|
Board thickness recommended at this power level |
|
Cannot find suitable component in the current set |
|
K-package power is based on IR reflow |
|
Selected diode heatsink may get too hot |
|
Clamp current cannot be calculated |
|
Estimated clamp voltage cannot be calculated |
|
Maximum operating flux density (BM) has been exceeded |
|
Zener Clamp loss (PZ) is greater than 3 W and may overheat |
|
Device may be too small for this power level (PO) |
|
Device may be too small for this output power level (PO) |
|
Peak DRAIN-SOURCE voltage exceeds device breakdown (BVDSS) |
|
Peak current exceeds derated minimum current limit |
|
The number of primary winding layers (L) is greater than recommended |
|
Maximum duty cycle (DMAX) limit has been exceeded |
|
Peak DRAIN-SOURCE voltage is within 20 V of device breakdown (BVDSS) |
|
Transformer size may be too small for this power level (PO) |
|
Peak flux density (BP) limit has been exceeded |
|
Gap Length (LG) is smaller than the practical limit |
|
Gap Length (LG) is larger than the practical limit |
|
Primary circular mils per amp (CMA) is below the recommended minimum |
|
CMA may be excessive |
|
Peak flux density (BP) is less than 1000 G and is excessively low |
|
Primary current density is greater than maximum recommended |
|
Peak flux density (BP) is less than 100 mT and is excessively low |
|
High output ripple current warning |
|
Wire gauge (AWG) is greater than recommended maximum |
|
Wire diameter (DIA) is less than recommended minimum |
|
Wire outer diameter is greater than maximum |
|
Over-Voltage (OV) protection is set too high |
|
Bias voltage should be at least 8 V for secondary feedback |
|
KI is less than 50% of the internal current limit |
|
The value of RPL is too large |
|
The working voltage of the RLS1 resistor can be too low |
|
The working voltage of the RLS2 resistor can be too low |
|
The working voltage of the RPL1 resistor can be too low |
|
The working voltage of the RPL2 resistor can be too low |
|
The power rating of the resistor is too small |
|
Full load operating frequency has been reduced |
|
Overload PO has been increased |
|
Peak current may exceed device ILIMITMAX value |
|
Peak primary current kept to safe level |
|
Transient KP is less than minimum level |
|
High flux density |
|
Regulation tolerances do not account for drift and other effects |
|
DCON is too small |
|
Bias resistor value may be too large |
|
The peak flux density is greater than 3200 Gauss (320 mT) |
|
The primary wire gauge is less than the recommended minimum (DPA) |
|
Dual output design |
|
Low output voltage design |
|
Winding wire exceeds 0.45 mm outer diameter (SI units) |
|
Margin exceeded |
|
Margin exceeded |
|
Wire gauges thicker than AWG 24 not recommended |
|
Wire size thicker than 0.55 mm not recommended |
|
Safety violation |
|
Safety violation |
|
Safety violation |
|
Safety violation |
|
Transformer leakage inductance increased |
|
Secondary "start" pin on Primary side |
|
Secondary "finish" pin on Primary side |
|
Secondary RTN pin on Primary side |
|
Synchronization between parameters |
|
Synchronization between parameters |
|
Single negative output designs are not supported |
|
Duplicated pin(s) |
|
Part already exists in component database |
|
Outputs below 2.5 V are not recommended to be used as the main outputs |
|
Design contains custom components not present in the database |
|
For language change to take effect please restart the application |
|
Editing of the Component Library while designs are open |
|
Peak power is less than continuous power |
|
No database part found |
|
The opened design uses an existing component set but its contents differ |
|
Component(s) in loaded design is different from those in the component library |
|
Changes have been made to the component library/set |
|
Confirm the permanent removal of a component set |
|
Unable to configure equal outputs as AC or DC stacked |
|
Unable to configure more than one DC stacked output |
|
Unable to configure single output as AC(DC) stacked |
|
Unable to configure only one output as Common RTN |
|
Not enough turns on main output to create stack combination with main output |
|
Unable to configure main output as DC stack base |
|
Unable to configure more than one positive output as Common RTN |
|
Unable to configure DC stacked output as AC stack base |
|
Unable to configure positive output as Common RTN if stack exists |
|
Actual number of pins available on bobbin is not enough to build the transformer |
|
Width of margin tape exceeds available bobbin width |
|
Margin tape is too wide. Effective Bobbin width is less than 1 mm |
|
For best EMI performance NFB should be set to the suggested value |
|
Magnet wire is used in a non-margin transformer |
|
Bias winding parameter is too small |
|
RF2 resistor value is too small and may consume more power. |
|
RF1 resistor value is too small and may consume more power. |
|
RF2 resistor value is too big and may not provide bias for TL431 |
|
RF1 resistor value is too big and may not provide bias for TL431 |
|
RF3 resistor value is too large |
|
Value of compensation capacitor CF1 is too small |
|
Target crossover frequency is too high. |
|
RF5 is too high |
|
CF3 is too low |
|
Optocoupler CTR is set too high |
|
Estimated Phase margin is too low |
|
Component sets can only be edited when there are no designs open |
|
Unfreeze VIN on Feedback Components Dialog |
|
Soft finish circuit capacitor value is too small |
|
Rated voltage of optocoupler is too low |
|
Crossover frequency is too high and cannot be calculated |
|
BOM Uploading page opening |
|
KP is too low |
|
KP is too high |
|
CMS is low (high Current Density) |
|
High Current Density |
|
Feedback current too high |
|
Feedback pin current too low |
|
RFB Resistors with 1% tolerance are recommended |
|
RSENSE Resistor(s) with 1% tolerance are recommended |
|
Rated Voltage of Varistor is too low |
|
MOV not present |
|
MOV Rated Current is too low |
|
Rated voltage of resistor may be exceeded |
|
Harmonic Limit Exceeded |
|
Device current limit exceeded |
|
Dissipation of RSENSE is too high |
|
PI Device is too big for selected output power |
|
Device too small |
|
KP too low |
|
LNK-PH-PL Output tolerance is too high |
|
MOV Clamping Current too low |
|
Output Voltage is too low |
|
Feedback pin bypass capacitor not in database |
|
Clamp capacitor not found in the database |
|
The appropriate TVS diode was not found in the component library |
|
RCD/RCDZ clamp not possible. TVS clamp used |
|
RCD/RCDZ clamp not possible. TVS clamp used |
|
Not enough clamp safety margin |
|
Bias damping resistor not valid |
|
RCD clamp design invalid |
|
AROTE_ACT out of recommended range |
|
Wrong SR FET Selection |
|
Cannot find SR FET in database |
|
VOUT pin voltage too high |
|
VOUT pin voltage too low |
|
Wrong VOUT-Pin transistor type selected |
|
Wrong VOUT-Pin transistor Current Rating selected |
|
Wrong VOUT-Pin transistor Voltage Rating selected |
|
OV_RATIO_ACTUAL is too high |
|
Max RBIAS greater than min required RBIAS |
|
RBIAS selection is out of range |
|
IB_MAX is too low |
|
IB_MAX is too high |
|
IB_MIN is too low |
|
IB_GAIN is too low |
|
VO less than VOmain stacked |
|
SR AUX output in AC Stack |
|
SR AUX output as CommonRTN |
|
Negative output is set as Common RTN with non-main output |
|
VOmain out of stack |
|
Foil Wrap margin too small |
|
FWD Pin Rating Exceeded | |
Device PCB Heatsink Area Exceeds Recommended limits |
|
Device PCB Heatsink Area is Close to Recommended limits |
|
Device on time may exceed maximum |
|
Device off time may be below minimum |
|
Output Voltage is too high |
|
Primary circular mils per amp low |
|
CMA below recommended |
|
Incorrect VOQC Input |
|
RBIAS is not delivering sufficient current to the bias |
|
PDP is not standard for small power |
|
PDP is not integer for high power |
|
One of Set-Point is higher than PDP |
|
VOPPSMAX low |
|
VOPPSMIN high |
|
USBPD Compliance failed - less setpoints |
|
USBPD Compliance Test failed - non standard |
|
Check counterpart parameters |
|
Set-Point is higher than 5 A |
|
Set-Point is higher than 3 A |
|
Feedback Type Incompatible with Output |
|
Switched Feedback Network Incompatible with Output |
|
KP is too low, zero or negative |
|
KP is less than 0.4 |
|
Device On-time violated |
|
Set-Point Voltage is higher than 20 V |
|
Maximum Programmable Voltage is higher than 21 V |
|
Minimum Programmable is not 3.3 V |
|
Clamp capacitor voltage rating is too low |
|
Bias capacitor voltage rating is too low |
|
Output bulk capacitor voltage rating is too low |
|
Output post filter capacitor voltage rating is too low |
|
Fully utilized Transformer winding window |
|
BaseLine Set-Point missing |
|
The value is outside allowed range |