Notification 652 - Not enough clamp safety margin
CATEGORY
ISSUE / RESULT
FIX / REFERENCE(S)
Information
The margin between the drain voltage ring and the primary Switch breakdown voltage is less than 40V.
Decrease the VOR, VC_GOAL or pick a device with a higher BVDSS.