Notification 652 - Not enough clamp safety margin 

CATEGORY

ISSUE / RESULT

FIX / REFERENCE(S)

Information

The margin between the drain voltage ring and the primary Switch breakdown voltage is less than 40V.

  • Decrease the VOR, VC_GOAL or pick a device with a higher BVDSS.