CATEGORY
ISSUE / RESULT
FIX / REFERENCE(S)
Information
The calculated value of DCON is smaller than DCONmin (4.5 µs) and can result in poor output regulation.
Increase DCON to greater than 4.5 µs.
ReduceVOR, or design with a smaller device.