Notification 692 – VOPPSMAX low |
||
CATEGORY |
ISSUE / RESULT |
FIX / REFERENCE(S) |
Error |
The Maximum programmable voltage is lower than the maximum Baseline Set Point Voltage. This is not allowed by the USBPD Standard |
The USBPD Standard specifies the required Programmable range to be advertised as a function of the maximum PDO voltage. VOPPMIN = 3.3 V (constant). VOPPMAX ≥ 5.9 if PDP<=15, VOPPMAX ≥ 11 if 15<PDP<=27, VOPPMAX ≥ 16 if 27<PDP<=45, VOPPMAX ≥ 21 if PDP>45 |