Notification 141 - Selected diode has insufficient margin to its rated current

CATEGORY

ISSUE / RESULT

FIX / REFERENCE(S)

Error

One of the selected diodes has insufficient margin to its rated current specification.

The diode may fail due to continuous operation at a high temperature caused by the insufficient margin to the diode's rated current

  • Verify thermal performance of a prototype using the selected diode

  • Choose a diode with a higher current rating